Se rendre au contenu
PCAN-MiniDisplay
v1.4.2
1.4.2 30/04/2020
Améliorations
- Added support for digital output in scenes
- New parameter "keep previous value" added for digital output in scenes
1.4.0 21/11/2019
Corrections de bugs
- Trace Messages: If nothing was selected to be traced, the help file was not displayed
Changements
- Trace Messages: If nothing is selected to be traced, a warning shows "No trace data selected."
1.3.12 08/10/2019
Améliorations
- Instruments: Added the keyword "protect=1" for section [global]. A compressed instrument is encrypted and does not run on another device
Corrections de bugs
- Data records of error frames were sometimes incorrect and did no contain the correct bus number
- Data records of error-frames did not have the correct DLC (set to 4)
- In case of a Bus-Off during transmission of tx-lists in a scene the bus was not set back to Bus-On again
1.3.11 01/10/2019
Améliorations
- Added the trace modes multi file and single session. This allows continuous logging onto the SD card
1.3.10 02/09/2019
Améliorations
- Added differnt logger operation modes: single file, multi file linear, and multi file circular
1.3.9 27/08/2019
Corrections de bugs
- Timestamps are only 32 bit, in case the logger splits the data into several files it was not possible to create the correct timestamp per file
- The header of each log file now contains a 64 bit timestamp. An update of the PEAK-Converter tool is required to make use of the 64 bit timestamps
1.3.8 25/03/2019
Améliorations
- Enums are now supported in instruments
- The format-strimg for labels can be omitted if only a simple number should be displayed (e,g, "%d", "%u", "%f" ). The format-string is automatically selected based on the datatype of the variable (unsigned, signed, float, string, enum)
- The format-string can be used for more complex outputs, e.g. "%03d °C", "%5.2f mV" etc.
- The plotter can scroll the x-axis. For this, define scroll_x=[0|1]
1.3.6 07/01/2019
Corrections de bugs
- In case of a multiplexed messages, the wrong variable was used as a multiplexer. Therefore the multiplexed variables were not updated correctly
1.3.5 10/09/2018
Améliorations
- Instruments: No text output while a compressed instrument is loaded
- Instruments: The display brightness can be adjusted via CAN. For this, define the variable "dev_brightness" with type unsigned and the value range is 0 to 100. If a scene makes use of this, brightness is set to minimum at startup of the scene
- Instruments: The buzzer can be activated via CAN. For this, define the variable "dev_buzzer" with type unsigned. Value range is 0 (off) and 1-14 for different predefined sounds
- Instruments: The keys enter, up, and down can be addressed via CAN. For this, define the variable "dev_keys" with type unsigned and the values 1=Enter, 2=KeyUp, and 3=KeyDown
1.3.4 20/08/2018
Corrections de bugs
- Correction in parsing of *.ins files
- Scenes did not schow ° when using newer modules with TFT display
1.3.3 21/06/2018
Corrections de bugs
- Plotter could not display signed data correctly
1.3.2 24/05/2018
Changements
- Bug fix: Tracer settings (type of trace) were not stored correctly, therfore automatic trace start after power-on did not capture the desired data.
1.3.1 07/12/2017
Changements
- Added a new option to the device settings to swap the display orientation (0°/180°)
- Added a new feature: Scenes can now transmit CAN frame sequences. For this there are 3 types of transmit lists: init list, cyclic list, and exit list
1.2.3 28/07/2017
Changements
- The transparency parameter of instruments can now be set to 2 which enables a recalculation of overlapping transparent instruments
1.2.1 17/06/2017
Changements
- Several changes in Device Settings due to the new hardware version and to increase the readability
1.1.7 19/06/2017
Améliorations
- In addition to decimal, the parameter muxvalue of instruments can be defined in hexadecimal
- Added a new tracer option to set a shutdown time (Tracer timeout) in case no error/data is received for this time
- Added display dimming with timeout
Corrections de bugs
- Bitrate detection was not working correctly since version 1.1.3
- The playing back traces with channel 2 was not working
- Fixed reset of CAN channel 2
1.1.5 04/11/2016
Améliorations
- Added logging and playback support
- The log file size can be selected by user now
- The information to be logged can be chosen by the user (error, data, or error and data)
- New for instrument panels: Possibility to use multiplexed CAN signals
- New for instrument panels: if a signal of a label has a timeout, a special timeout string can be displayed
1.1.2 22/06/2015
Améliorations
- Added help files
- When an instrument file is quit, the system returns to the Instrument Selection menu instead of the Main menu
Corrections de bugs
- Displaying Bitmaps did not work since version 1.1.0
- The plotter draws one horizontal line out of its range
1.1.0 28/05/2015
Corrections de bugs
- Depending on the memory card type, access to the memory card might fail
- The CAN filter could be set incorrectly after enter/exit the Device Settings menu
- Shutdown did not always work
Neutralisé