PCAN-MiniDiag FD
v1.4.121.4.12 28/01/2020
Changements
- Added support for a new hardware revision
1.4.11 22/01/2020
Corrections de bugs
- In some cases a recessive CAN-Low voltage was displayed in the CAN Voltages menu as a dominant voltage
- At module startup the voltage measured at D-Sub pin 9 was sometimes displayed wrong
- In case that the differential CAN bus voltage was > 10 V or < -10 V the displayed value was sometimes not correct
1.4.10 13/05/2019
Améliorations
- Added the CAN differential voltage to the CAN Voltages device function
- Added a new device function to show maximum, minimum, and average values of the differential voltages of the dominant and recessive levels
- Reworked the text coloring. Added a color scheme for evaluation of bus load, termination, and error counter measurement values
Corrections de bugs
- Improvement of automatic bit rate detection
- If the bitrate was set manually, in some cases the CAN controller was initialized with the wrong bit rate
- If the bitrate was set manually, in some cases the initially selected bitrate was not one which was currently set
- After a successful bit rate detection sometimes the new bit rate was not displayed. Instead the initial text "Press * to set or
to detect the bit rate" was shown and the CAN controller was not initialized with the detected bit rate - It was possible that the ADC-mutex could cause a system shutdown
- In some cases when the bit rate was set manually to non-iso mode, the CAN controller was initialized in iso-mode
- In some cases the automatic bit rate detection failed for bit rates smaller than ~52kbit/s
- Optimization of CAN voltage measurement
1.4.0 29/01/2019