PCAN-MicroMod FD
v1.11.1
1.11.1 23/10/2025
Corrections de bugs
- Message trigger function in mode "equal" did never trigger if tolerance was set to zero (epsilon=0)
- Now any channel can be used for rotary encoder independently instead of subsequent channels only
- Offset of 16 bit analog inputs did not always work correctly
- Function "conditinal copy" did always write back the current result into the output variable. Now the output variable is only updated in case the condition was true
1.10.5 30/01/2025
Corrections de bugs
- In some cases the 16 bit ADC was not initialized correctly
- In some cases the frequency input measurement was incorrect
1.10.4 30/08/2024
Changements
- Internal optimizations for production
1.10.3 09/07/2024
Améliorations
- Added support for the new PCAN-MicroMod FD ECU. For this hardware type additional features were added:Added support for a sleep mode and Wake-up via CANThe serial number of the PCAN-MicroMod FD ECU is set during the production process and can be read via PEAK-Flash later onFor the PCAN-MicroMod FD ECU the module ID can be set with a configuration via the configuration softwareAdded multiple configuration options available via the Device Parameters service introduced with the latest configuration software
- Added support for external transceivers for the PCAN-MicroMod FD Evaluation and custom boards
- Added support for new configuration options and functions:New option "Disable config read-back" to disable reading a configuration from a module via the softwareNew statistic types: bus load tx, rx, and totalNew function: Counter with ReloadNew function: Copy ConditionalNew function: PID
- Added support for a sleep mode and Wake-up via CAN
- The serial number of the PCAN-MicroMod FD ECU is set during the production process and can be read via PEAK-Flash later on
- For the PCAN-MicroMod FD ECU the module ID can be set with a configuration via the configuration software
- Added multiple configuration options available via the Device Parameters service introduced with the latest configuration software
- New option "Disable config read-back" to disable reading a configuration from a module via the software
- New statistic types: bus load tx, rx, and total
- New function: Counter with Reload
- New function: Copy Conditional
- New function: PID
Corrections de bugs
- At high transmit busloads it was not possible to reconfigure the module
- Fixed possible undefined behavior in case the tx-CAN queue is full
- Further minor bug fixes
1.10.0 03/05/2022
Corrections de bugs
- In case less than 4 inputs were used in function block "ADD", the value of an unused input might not had been 0 and lead to a wrong result
- In rare cases, a transmit message was missing
Changements
- Board types Eval and Custom are now exchangable; this means a CPU can be configured on one board type and used on the other board type
- Added check for authentification during configuration
1.9.11 28/01/2021
Changements
- Timeout-detection for frequency-input measurement did not work correctly in all cases
- Signed variables were sometimes calculated wrong
1.9.10 02/08/2020
Corrections de bugs
- Inversion of digital inputs did not work always correctly
1.9.9 09/07/2020
Corrections de bugs
- Motherboard Analog1: negative analog input values were incorrect in case a scale value not equal 1 was used
1.9.8 05/06/2020
Changements
- In case the configuration of a DR module is invalid, but bit rate turn switches are valid, the CAN engine is initialized according to the switch position and the module runs in Standard (not CANopen) mode
- The bit rate table for non-DR modules did contain a samplepoint of 87.5% for 500 kbit/s, CAN FD without BRSs. Corrected to a samplepoint of 80%
1.9.7 12/05/2020
Améliorations
- Enhanced PEAK-Flash identification
Corrections de bugs
- PCAN-MicroMod FD Analog 1 modules with serial numbers from 00100 to 00143 might return incorrect Analog Input (16-bit) results in +/-20V measurement range (~2.5% too high)
1.9.6 09/04/2020
Améliorations
- Added more configuration and board specific information when detecting the CPU module or the different motherboards with the configuration software
- Added new module descriptions for PEAK-Flash
Corrections de bugs
- Updated the bit rate table due to some bugs
- PWM measurement of channel 1,3, and 5 was inactive
Changements
- SSP (secondary sample point) of data bit rates is set to 80% for bit rates >= 2.5 Mbit/s
- If no valid configuration is loaded the module blinks red and green alternately
- Frequency of digital outputs in PWM mode was changed from integer to float
1.9.5 14/02/2020
Changements
- Improvement: New scale calibration for +/-20V range of 16-bit analog inputs
1.9.2 18/12/2019
Changements
- Bug fix: Reading module information did not initialize transfer counter correctly
1.9
Changements
- Bug fix for digital inputs: Option to invert the signal was missing in the configuration
1.8
Changements
- I2C-EEPROM was removed. Binary configuration is now stored in QSPI flash
1.6 28/08/2019
Changements