Se rendre au contenu

Plotter Add-in 6

v6.8.1
VersionDate
6.8.1 12/08/2025 Détails
6.8.0 19/12/2024 Détails
6.7.0 09/02/2024 Détails
6.6.1 22/12/2022 Détails
6.6.0 14/06/2022 Détails
6.5.0 22/09/2021 Détails
6.4.1 04/12/2020 Détails
6.4.0 30/10/2020 Détails
6.3.5 17/02/2020 Détails
6.3.1 07/06/2019 Détails
6.3.0 26/03/2019 Détails
6.2.1 31/08/2018 Détails
6.2.0 20/07/2018 Détails
6.1.1 12/01/2018 Détails
6.0.12 09/06/2017 Détails
6.0.11 07/04/2017 Détails
6.0.7 04/11/2016 Détails
6.0.1 09/06/2016 Détails

Version 6.8.1 12/08/2025

Corrections de bugs
  • When importing data from a Tracer, the 'Zoom X-Axis to fit imported data' option only had an effect if the 'Zoom Y-Axis' function was enabled at the same time

Version 6.8.0 19/12/2024

Améliorations
  • Handling of Out-of-Memory errors improved
Corrections de bugs
  • Channel fill could overlap other channel drawing areas if Y-axes were stacked one above the other

Version 6.7.0 09/02/2024

Corrections de bugs
  • The last screen position of the Properties dialog was not correctly restored when opened
  • If a Y-axis did not use the full available height in the Plotter window, a data cursor having the “Value-Y” style did not measure/display values correctly

Version 6.6.1 22/12/2022

Améliorations
  • Performance of loading and saving of files greatly improved, and load/save operations consume much less RAM
Corrections de bugs
  • A data cursor showed the signal unit in its tooltip even if the data cursor was configured to show only the x-value
  • If a Y-axis did not use the full available height in the Plotter window, a data cursor having the 'Peak-Peak' style did not measure/display values correctly
  • A few corrections in the German translation of the user interface

Version 6.6.0 14/06/2022

Améliorations
  • New command to create a new Y-axis for a specific channel
  • New possibility to rotate the Y-axis title 90 degrees so that it is displayed horizontally
Corrections de bugs
  • Object Model: After changing the Y-axis of a channel in the Properties dialog window, the Channel.YAxis property still returned the previous Y-axis

Version 6.5.0 22/09/2021

Corrections de bugs
  • Assigning a signal to a channel in the Properties dialog box did not adjust the name and title of the channel according to the signal name if the Plot initially had been loaded from a file

Version 6.4.1 04/12/2020

Améliorations
  • New Unit column can be included in the Legend
  • Automation interface: Added new Channel.Unit property and new Legend object to support automating the appearance of the legend

Version 6.4.0 30/10/2020

Améliorations
  • When importing data from a tracer, a status bar will be displayed with information about the progress while the trace is being searched for signals and while the actual import is in progress

Version 6.3.5 17/02/2020

Améliorations
  • Automation Interface: New methods Plotter.ExportToCSV and Plotter.SaveImage

Version 6.3.1 07/06/2019

Améliorations
  • New option to create separate Y-axes for signals imported from a tracer, to reproduce behavior of PCAN-Explorer 5
Corrections de bugs
  • When a new channel or y-axis was added in the Properties dialog box, the settings from the User Defaults file were not applied
  • Names of y-axes could not be changed in the Properties dialog box

Version 6.3.0 26/03/2019

Améliorations
  • New possibility to export fully qualified names of signals when exporting data to a CSV file
Corrections de bugs
  • Selecting the Set Master Axis command from the Y-axis context menu triggered an Access Violation error

Version 6.2.1 31/08/2018

Corrections de bugs
  • If signals were imported from a Tracer into the Plotter a Runtime Error 216 (Access Violation) could occur when PCAN-Explorer was closed

Version 6.2.0 20/07/2018

Améliorations
  • New possibility to choose custom font colors for the various textual elements in a plotter window
  • New data cursor command to find the timestamp of a data-point in an open Trace window (only for tracers with buffer types dynamic, ring, and linear)
Corrections de bugs
  • When signals were imported from a tracer, the Select Signals to Import dialog box could be displayed behind the main PCAN-Explorer window

Version 6.1.1 12/01/2018

Corrections de bugs
  • The X-Axis Span drop-down list was not updated with the value from a loaded plotter file

Version 6.0.12 09/06/2017

Améliorations
  • New option to control whether Y-axis scale labels can be replaced by enum strings of signals

Version 6.0.11 07/04/2017

Corrections de bugs
  • When a new cursor was added to a Plotter while the Cursor display was enabled in the toolbar, the new cursor was not initially visible. To make the new cursor visible, the Cursor option had to be toggled off and on again in the toolbar
  • Newly added cursors used a different font to draw the cursor value tooltip window than the predefined first cursor

Version 6.0.7 04/11/2016

Corrections de bugs
  • After assigning a signal to a channel in the Properties dialog box on the Channels page, the channel name was not correctly set to the signal name if the signal was part of a multiplexer definition
Changements
  • Additional quick-select values in the X-Axis span drop-down list (100 ms, 500 ms, 1 s, 24 hrs)

Version 6.0.1 09/06/2016

Changements
  • Decoupling of the configuration of Y-axis and channels to improve presentation and handling
  • First Release
Neutralisé