Se rendre au contenu

PCAN-Explorer 6 — Version 6.2.0

20/07/2018
Améliorations
  • New option "Show timestamps in Macro Status window"
  • New Standard Macro instructions CheckId, CheckMsgType, and ClearOutput
  • Column "Connection" of Receive/Transmit lists separated into "Connection" (connection name) and "Net Connection" (NetName@DeviceName), and in Connection Window renamed to "Net Connection"
  • New columns "Hardware" and "Filter" in the Connections window
  • New column "ID" in the Timing Errors Window and in the timeouts log file
  • New option "Allow multiple instances" in the External Tools dialog box
  • New command for Trace windows to find the timestamp of a selected message in an open Plotter window
  • New possibility to register transmit callback functions in Add-ins
  • Object model: New property AddIn.ExtensibilityObject
  • New possibility to include Callback DLLs in a project
  • Added new example projects for Add-ins and Callback DLLs
  • The previously hidden option to create a Debug Logfile is now accessible in the Options dialog box
  • Improvements in the setup program to eliminate digital signature verification problems under Windows®7
Corrections de bugs
  • If a Trace file was exported with the option "Signals - CSV", the timestamps were not exported with the selected decimal separator
  • Changing the Data Bytes per Row or Data Bytes per Column values in the Receive/Transmit hex-view area via the context menu triggered an exception error
  • Motorola float variables and Motorola signed/unsigned variables that were not aligned to data byte boundaries were incorrectly decoded if the underlying CAN message had more than 8 data bytes
  • Object Model: Access violation in method Windows.Add if an unknown GUID was specified
  • The internal calculation of the minimum message length for symbols without a data length specification failed if the symbol contained only a single one-bit variable at bit position 0
  • After manually adding an Add-in in the Add-in Manager dialog box, the Tools menu was not immediately updated so the Add-in's commands were not visible
  • If the option "Valid for all Data Lengths" was enabled for a CAN FD symbol/multiplexer, variables located beyond the first 64 bits could not be decoded in the Receive List
  • The automatically determined default data length of CAN FD transmit symbols/multiplexers could be invalid, since CAN FD allows only a specific set of data lengths, which was not taken into account
  • If a connection has been removed in the Connections Window and then a new one has been added, an error message "Error - Property BitRate does not exist" was displayed
  • If a J1939 source address was specified in the CAN ID of a symbol that differed from the Preferred Address of the connection, then any transmit message created by the Instruments Panel based on such a symbol had a wrong CAN ID, since the default behavior of PCAN-Explorer was to insert the preferred/claimed address as the source address
  • Some other minor bug fixes and improvements
Changements
  • The OnApplicationShutDown event was triggered only after all documents and windows were closed. Now the event is triggered before to give all windows the possibility to react to it
Neutralisé