Skip to Content
PEAK-System

PCAN-Ethernet Gateway FD DR

Reference Product Price excl. VAT Quantity
IPEH-004012 PCAN-Ethernet Gateway FD DR - 2 x CAN FD to LAN Gateway in DIN rail plastic casing 638.00 €
IPEH-004012
PCAN-Ethernet Gateway FD DR - 2 x CAN FD to LAN Gateway in DIN rail plastic casing
638.00 €
638.00 € 638.00 €

Terms and Conditions
30-day money-back guarantee
Shipping: 2-3 Business Days

CAN FD to IP network gateway in DIN rail housing

The PCAN-Ethernet Gateway FD DR provides access to both classic CAN buses and CAN FD buses via an IP network. Several units can also link CAN buses together over the IP protocol. CAN frames are encapsulated in TCP or UDP packets, then routed via the IP network to a remote device. This module features one LAN port and two CAN FD interfaces supporting bit rates of up to 10 Mbit/s. An AM5716 Sitara processor supplies the required computing power.

The PCAN-Gateway range is configured via an intuitive web interface. The JSON interface provides an alternative for software-based control. Both access methods provide information on device status, settings, communication interfaces, message routing and filters.

The CAN FD (Flexible Data rate) standard is mainly distinguished by an increased data transfer capacity. Each frame can carry up to 64 bytes of payload data (compared with 8 previously) at a bit rate of up to 10 Mbit/s. CAN FD maintains backward compatibility with the CAN 2.0 A/B standard, allowing CAN FD nodes to be integrated into an existing CAN network (the extended CAN FD features cannot, however, be used in this case).

  • Two high-speed CAN channels (ISO 11898-2)Complies with CAN 2.0 A/B and FD specificationsCAN FD data transfer rate (max. 64 bytes) from 20 kbit/s to 10 Mbit/sCAN transfer rate from 20 kbit/s up to 1 Mbit/sMicrochip MCP2558FD CAN transceiver
  • Complies with CAN 2.0 A/B and FD specifications
  • CAN FD data transfer rate (max. 64 bytes) from 20 kbit/s to 10 Mbit/s
  • CAN transfer rate from 20 kbit/s up to 1 Mbit/s
  • Microchip MCP2558FD CAN transceiver
  • Galvanic isolation up to 500 V between all CAN channels, between the RS-232 channel and the power supply
  • Connections for CAN, RS-232, and power supply via a 4-screw Phoenix terminal block connector
  • LAN connectionData transmission via TCP or UDPBit rate of 10/100/1000 Mbit/sRJ-45 connector with status LEDs
  • Data transmission via TCP or UDP
  • Bit rate of 10/100/1000 Mbit/s
  • RJ-45 connector with status LEDs
  • Device monitoring and configuration via the web interface or the JSON interface
  • Software update via the web interface
  • Restart or reset the device to a previous software version using a reset button
  • Plastic housing (width: 45.2 mm) for DIN rail mounting (DIN EN 60715 TH35)
  • Device status and power LEDs
  • Mini PCI Express slot, USB port and RS-232 connector for future use
  • Supply voltage 8 to 30 V
  • Operating temperature range from -40 to +70 °C
  • Fan for active cooling when a temperature limit is exceeded

With the PCAN-Gateways, CAN buses can be connected via LAN or WLAN. CAN frames are wrapped into TCP or UDP message packets and then forwarded from one device to another. Based on this technology, it is possible to connect CAN networks over a great distance.

The configuration of the PCAN-Gateway product family is done via a convenient web interface. For this, the device must be connected to the PC via LAN or WLAN, depending on the used model. The web interface can be opened with a common browser. After a successful login you get access to all information and the configuration of the device settings, communication interfaces, message forwarding, and filters.

Alternatively, the JSON interface is available for access. This allows the development of software to automatically monitor and configure all devices connected to the IP network.

Functions of the web interface
  • Clear presentation of information about device settings, communication interfaces, message forwarding, and filters
  • Definition of the public visibility of status information
  • Import and export of device configurations
  • Reset of the device configuration to factory defaults
  • Comfortable software updates
  • Scan of the IP network for further available PCAN-Gateways for an easier establishment of routes
  • Layout automatically adjusts for mobile devices
  • Rebooting the device via the website
  • Enabling, disabling, and configuration of the JSON interface
  • Integrated help pages
CAN channels settings
  • Selection of bit rates up to 1 Mbit/s from a preset list
  • Setup of user defined bit rates via register values
  • Status switching of the listen-only mode
LAN interface settings (if available)
  • Automatic or manual setup of the device‘s IP address (IPv4) and the subnet mask
WLAN interface settings (if available)
  • Set the WLAN operating mode to Infrastructure (Client), Ad-Hoc, or Access Point
  • Automatic or manual setup of the device‘s IP address (IPv4) and the subnet mask
  • Connection to the wireless network
  • Configuration of the network encryption
Setup and management of the message forwarding
  • Setup of the message forwarding between a CAN channel and LAN/WLAN (or vice versa)
  • Selection of the participating CAN channel
  • Definition of the LAN/WLAN station according to the IP address and the port
  • Selection of the transfer protocol TCP or UDP
  • Enabling, disabling, and editing of existing routes
  • Disabling the PCAN-Gateway Handshake to allow the connection to other devices
Properties of the message filtering
  • Creating and managing filters via a new section of the web interface
  • Creating Filters with different options:
    • Filtering messages with 11-bit or 29-bit IDs
    • Support of range and mask filters
    • Optional inversion of the filter range
  • Assigning a filter to multiple routes
Functions of the JSON interface
  • Receiving of a request as a JSON-formatted GET parameter of an HTTP request
  • Returning of the response in JSON format
  • Reading out authorized information about device settings, communication interfaces, message forwarding, and filters
  • Configuration of settings as well as adding and deleting message forwarding and filters (function is deactivated at delivery)
  • Alternative access to the JSON interface via an emulated shell view with integrated documentation for an easy start

  • PCAN-Ethernet Gateway FD DR in its DIN rail housing
  • Mating connectors for the CAN and RS-232 channels and for the power supply (Phoenix Contact MSTB 2,5/4-ST BK - 1756298)
  • RJ-45 network cable (2 m)
  • Manual in PDF format
  • Printed quick start guide

Package PCAN-Ethernet Gateway FD DR

This package is used to update the website, software and configuration of the PCAN-Ethernet Gateway FD DR (IPEH-004012).


Manual PCAN-Ethernet Gateway FD DR

PCAN-Gateway developer documentation

PCAN-Gateway developer tools and examples

This package contains code examples and a Wireshark dissector to help with the development of socket applications that connect to a PCAN gateway.


PCAN-Gateway Quick Start Guide

Virtual PCAN-Gateway Setup

This is the PEAK-System installation package containing tools and device drivers for Windows® 11 (x64/ARM64), 10 (x64).Note:Select "Virtual PCAN-Gateway" among the available options during installation.


Virtual PCAN-Gateway Manual

CAN FD to IP network gateway in DIN rail housing

The PCAN-Ethernet Gateway FD DR provides access to both classic CAN buses and CAN FD buses via an IP network. Several units can also link CAN buses together over the IP protocol. CAN frames are encapsulated in TCP or UDP packets, then routed via the IP network to a remote device. This module features one LAN port and two CAN FD interfaces supporting bit rates of up to 10 Mbit/s. An AM5716 Sitara processor supplies the required computing power.

The PCAN-Gateway range is configured via an intuitive web interface. The JSON interface provides an alternative for software-based control. Both access methods provide information on device status, settings, communication interfaces, message routing and filters.

The CAN FD (Flexible Data rate) standard is mainly distinguished by an increased data transfer capacity. Each frame can carry up to 64 bytes of payload data (compared with 8 previously) at a bit rate of up to 10 Mbit/s. CAN FD maintains backward compatibility with the CAN 2.0 A/B standard, allowing CAN FD nodes to be integrated into an existing CAN network (the extended CAN FD features cannot, however, be used in this case).

Neutralized