CAN to IP network gateway in DIN rail housing
The PCAN-Ethernet Gateway DR interconnects separate CAN buses over IP networks. CAN frames are encapsulated in TCP or UDP packets, then routed via the IP network to a remote device. This module has one LAN port and two high-speed CAN interfaces. Its DIN rail housing and extended temperature range make it suitable for industrial environments.
The PCAN-Gateway range is configured via an intuitive web interface. The JSON interface provides an alternative for software-based control. Both access methods provide information on device status, settings, communication interfaces, message routing and filters.
- Two high-speed CAN channels (ISO 11898-2)Complies with CAN 2.0 A/B specificationsTransfer rate from 5 kbit/s up to 1 Mbit/sTJF1441AT CAN transceiver
- Complies with CAN 2.0 A/B specifications
- Transfer rate from 5 kbit/s up to 1 Mbit/s
- TJF1441AT CAN transceiver
- Galvanic isolation up to 500 V between all CAN channels, between the RS-232 channel and the power supply
- Connections for CAN, RS-232, and power supply via a 4-screw Phoenix terminal block connector
- LAN connectionData transmission via TCP or UDPBit rates of 10/100 Mbit/sRJ-45 connector with status LEDs
- Data transmission via TCP or UDP
- Bit rates of 10/100 Mbit/s
- RJ-45 connector with status LEDs
- Device monitoring and configuration via the web interface or the JSON interface
- Software update via the web interface
- Restart and factory reset via a Reset button
- Plastic housing (width: 22.5 mm) for DIN rail mounting (DIN EN 60715 TH35)
- Device status and power LEDs
- RS-232 connector for serial data transfer (reserved for future use)
- Supply voltage 8 to 30 V
- Extended operating temperature range from -40 to +85 °C
With the PCAN-Gateways, CAN buses can be connected via LAN or WLAN. CAN frames are wrapped into TCP or UDP message packets and then forwarded from one device to another. Based on this technology, it is possible to connect CAN networks over a great distance.
The configuration of the PCAN-Gateway product family is done via a convenient web interface. For this, the device must be connected to the PC via LAN or WLAN, depending on the used model. The web interface can be opened with a common browser. After a successful login you get access to all information and the configuration of the device settings, communication interfaces, message forwarding, and filters.
Alternatively, the JSON interface is available for access. This allows the development of software to automatically monitor and configure all devices connected to the IP network.
Functions of the web interface
- Clear presentation of information about device settings, communication interfaces, message forwarding, and filters
- Definition of the public visibility of status information
- Import and export of device configurations
- Reset of the device configuration to factory defaults
- Comfortable software updates
- Scan of the IP network for further available PCAN-Gateways for an easier establishment of routes
- Layout automatically adjusts for mobile devices
- Rebooting the device via the website
- Enabling, disabling, and configuration of the JSON interface
- Integrated help pages
CAN channels settings
- Selection of bit rates up to 1 Mbit/s from a preset list
- Setup of user defined bit rates via register values
- Status switching of the listen-only mode
LAN interface settings (if available)
- Automatic or manual setup of the device‘s IP address (IPv4) and the subnet mask
WLAN interface settings (if available)
- Set the WLAN operating mode to Infrastructure (Client), Ad-Hoc, or Access Point
- Automatic or manual setup of the device‘s IP address (IPv4) and the subnet mask
- Connection to the wireless network
- Configuration of the network encryption
Setup and management of the message forwarding
- Setup of the message forwarding between a CAN channel and LAN/WLAN (or vice versa)
- Selection of the participating CAN channel
- Definition of the LAN/WLAN station according to the IP address and the port
- Selection of the transfer protocol TCP or UDP
- Enabling, disabling, and editing of existing routes
- Disabling the PCAN-Gateway Handshake to allow the connection to other devices
Properties of the message filtering
- Creating and managing filters via a new section of the web interface
- Creating Filters with different options:
- Filtering messages with 11-bit or 29-bit IDs
- Support of range and mask filters
- Optional inversion of the filter range
- Assigning a filter to multiple routes
Functions of the JSON interface
- Receiving of a request as a JSON-formatted GET parameter of an HTTP request
- Returning of the response in JSON format
- Reading out authorized information about device settings, communication interfaces, message forwarding, and filters
- Configuration of settings as well as adding and deleting message forwarding and filters (function is deactivated at delivery)
- Alternative access to the JSON interface via an emulated shell view with integrated documentation for an easy start
- PCAN-Ethernet Gateway DR in its DIN rail housing
- Mating connectors for the CAN and RS-232 channels and for the power supply (Phoenix Contact MSTB 2,5/4-ST BK - 1756298)
- RJ-45 network cable (2 m)
- Manual in PDF format
- Printed quick start guide
This package is used to update the website, software and configuration of the PCAN-Ethernet Gateway DR (IPEH-004010, serial number between 25000 and 28999 and above 31000).
This package is used to update the website, software and configuration of the PCAN-Ethernet Gateway DR (IPEH-004010, serial number between 1 and 24999 and between 29000 and 30999).
This package contains code examples and a Wireshark dissector to help with the development of socket applications that connect to a PCAN gateway.
This is the PEAK-System installation package containing tools and device drivers for Windows® 11 (x64/ARM64), 10 (x64).Note:Select "Virtual PCAN-Gateway" among the available options during installation.
CAN to IP network gateway in DIN rail housing
The PCAN-Ethernet Gateway DR interconnects separate CAN buses over IP networks. CAN frames are encapsulated in TCP or UDP packets, then routed via the IP network to a remote device. This module has one LAN port and two high-speed CAN interfaces. Its DIN rail housing and extended temperature range make it suitable for industrial environments.
The PCAN-Gateway range is configured via an intuitive web interface. The JSON interface provides an alternative for software-based control. Both access methods provide information on device status, settings, communication interfaces, message routing and filters.