Display and recording of CAN data

PCAN-MiniDisplay Case PCAN-MiniDisplay - Voltage Example PCAN-MiniDisplay - Process-Monitor-Pro Example PCAN-MiniDisplay - Process-Monitor Example PCAN-MiniDisplay - Bar Instrument Example PCAN-MiniDisplay - Plotter Example PCAN-MiniDisplay - Tacho Instrument Example

Designed as a human-machine interface, the PCAN-MiniDisplay allows CAN data to be visualized. Two high-speed CAN connectors provide the link to the CAN bus. The graphical display of incoming CAN data is predefined through a configuration and then rendered on a TFT screen.

The PCAN-MiniDisplay also offers a recording function: data traffic is logged to a memory card and can then be replayed or analyzed on a PC.

A variant of the product is available in a plastic housing fitted with push buttons. This version makes it easier to create and test configurations tailored to specific use cases. It also allows direct switching between several configurations while running.

Note


Displaying the configuration, recording, and replaying CAN messages cannot be performed simultaneously. The PCAN-MiniDisplay can only use one of these three functions at a time.

  • CAN connections via 2 High-Speed CAN channels (ISO 11898-2)Transfer rate from 40 kbit/s up to 1 Mbit/sCompliant with CAN 2.0 A/B specificationsNXP TJA1041 CAN transceiver with wake-up
  • Transfer rate from 40 kbit/s up to 1 Mbit/s
  • Compliant with CAN 2.0 A/B specifications
  • NXP TJA1041 CAN transceiver with wake-up
  • 2 analog inputs10-bit resolutionMeasuring range 0 to 16.5 V
  • 10-bit resolution
  • Measuring range 0 to 16.5 V
  • 1 digital input and 1 digital output
  • TFT screen with a resolution of 320 x 240 pixels
  • Freely configurable CAN data visualization via text files.Display of texts, CAN data, and analog and digital input values via text labelsFormattable CAN data output as integers, floating-point numbers, or strings, taking enumerations and multiplexers into accountDisplay of transparent bitmap imagesDisplay of image lists depending on the signalDisplay of multiple signal curves in the tracersConfigurable access to button and buzzer functions, as well as screen brightness, via CANSequential transmission of CAN frames at startup, during operation, and at the end of a configuration
  • Display of texts, CAN data, and analog and digital input values via text labels
  • Formattable CAN data output as integers, floating-point numbers, or strings, taking enumerations and multiplexers into account
  • Display of transparent bitmap images
  • Display of image lists depending on the signal
  • Display of multiple signal curves in the tracers
  • Configurable access to button and buzzer functions, as well as screen brightness, via CAN
  • Sequential transmission of CAN frames at startup, during operation, and at the end of a configuration
  • microSD™ memory card reader (max. 32 GB)
  • USB 2.0 port to access the memory card using a PC
  • Reading of configurations from the memory card
  • Optional automatic start of a single configuration or recording at power-up
  • Recording of incoming CAN messages on the internal memory card, optionally including any errors that occurred
  • CAN ID filtering for recordings, configurable separately for each CAN channel
  • Conversion of log data into various formats via Windows software
  • Playback of a recording with an optional loop function
  • Use of optional push buttons for the navigation menu and to switch between several display configurations
  • Wake-up function via the CAN bus
  • Dimensions: 80 x 55 mm
  • Supply voltage 7 to 30 V
  • Operating temperature range from -20 to +70 °C
  • Device housed in a plastic enclosure with 3 push buttons
  • Connection via terminal blocks (Phoenix)

  • PCAN-MiniDisplay with mounting frame
  • Cables for power supply, CAN, and digital inputs
  • Pre-installed 512 MB memory card
  • PEAK-Converter conversion software for Windows®
  • Configuration examples
  • Manual in PDF format
  • PCAN-MiniDisplay in a plastic housing with matching connectors (Phoenix Contact FMC 1.5/4-ST-3.5 - 1952283 & Phoenix Contact FMC 1.5/10-ST-3.5 - 1952348)
  • Pre-installed 512 MB memory card
  • PEAK-Converter conversion software for Windows®
  • Configuration examples
  • Manual in PDF format

PCAN-MiniDisplay Package

Package including the firmware, configuration examples, resources, the PEAK-Converter software, the device help, and documentation.


PCAN-MiniDisplay Manual

PEAK-Converter 3

Software for converting trace data into various file formats, for Windows® 11 (x64/ARM64), 10 (x64).

Display and recording of CAN data

PCAN-MiniDisplay Case PCAN-MiniDisplay - Voltage Example PCAN-MiniDisplay - Process-Monitor-Pro Example PCAN-MiniDisplay - Process-Monitor Example PCAN-MiniDisplay - Bar Instrument Example PCAN-MiniDisplay - Plotter Example PCAN-MiniDisplay - Tacho Instrument Example

Designed as a human-machine interface, the PCAN-MiniDisplay allows CAN data to be visualized. Two high-speed CAN connectors provide the link to the CAN bus. The graphical display of incoming CAN data is predefined through a configuration and then rendered on a TFT screen.

The PCAN-MiniDisplay also offers a recording function: data traffic is logged to a memory card and can then be replayed or analyzed on a PC.

A variant of the product is available in a plastic housing fitted with push buttons. This version makes it easier to create and test configurations tailored to specific use cases. It also allows direct switching between several configurations while running.

Note


Displaying the configuration, recording, and replaying CAN messages cannot be performed simultaneously. The PCAN-MiniDisplay can only use one of these three functions at a time.

Neutralized