CAN CC, CAN FD, and CAN XL Interface for High-Speed USB 2.0
The CAN interface PCAN-USB XL ensures an uncomplicated connection to CAN XL, CAN FD, and CAN CC buses via the USB port of a computer. Galvanic isolation of up to 500 Volts decouples the PC from the CAN bus. With its compact plastic casing, it is ideal for mobile applications.
The PCAN-USB XL is delivered ready to use with Windows® and Linux drivers, the PCAN-View monitoring software, and the PCAN-Basic API for developing applications with CAN connection. PCAN-Basic 5 and PCAN-View 6 support the new standard CAN XL.
CAN XL
CAN XL (Extended Data-Field Length) was designed to improve the cooperation of CAN and TCP/IP networks and to enable transmitting larger data streams for use cases such as ECU flashing and software updates. For this, the new standard provides bit rates of up to 20 Mbit/s and data transmission with up to 2048 bytes per message.
Pin assignment D-Sub
| 2 | CAN-L |
| 3 | GND |
| 6 | GND |
| 7 | CAN-H |
- CAN interface for High-speed USB 2.0 (compatible to USB 3.0)
- High-speed CAN connection (ISO 11898-2 2024)
- Complies with CAN specifications CAN CC (classic CAN 2.0), CAN FD, and CAN XL (ISO 11898-1 2024)
- CAN bit rates from 20 kbit/s up to 1 Mbit/s
- CAN FD data bit rates up to 8 Mbit/s
- CAN XL data bit rates up to 8 Mbit/s, CAN FD compatible transmission mode
- CAN XL data bit rates up to 20 Mbit/s by using the transceiver mode switch
- CAN bus connection via D-Sub, 9-pin (in accordance with CiA® 106)
- Time stamp resolution 1 µs
- FPGA implementation of the CAN XL core by PEAK-System;
validated with the CAN XL Evaluation Board by C&S (www.cs-group.de) - CAN SIC XL transceiver TI TCAN6062V
- Galvanic isolation between CAN and USB up to 500 V
- CAN termination can be activated through solder jumpers
- Voltage supply via USB
- Extended operating temperature range from -40 to +85 °C (-40 to +185 °F)
- IPEH-005022: PCAN-USB XL in plastic casing
- Device drivers for Windows® 11 (x64/ARM64), 10 (x64), and Linux
- CAN monitor PCAN-View for Windows®
- Programming interface PCAN-Basic for developing applications with CAN CC, CAN FD, and CAN XL connection
- Programming interfaces for standardized protocols from the automotive sector
- Manual in PDF format
PEAK-System installation package containing tools and device drivers for our PC interfaces for Windows® 11 (x64/ARM64), 10 (x64). Tools included: PEAK Settings, PCAN-View, PLIN-View Pro and Virtual PCAN-Gateway. APIs included: PCAN-Basic, PLIN-API and PCAN-RP1210.
Device driver for PEAK CAN interfaces from kernel 2.6 onward.
Software for displaying, transmitting, and recording CAN CC, CAN FD, and CAN XL messages for Windows® 11 (x64/ARM64), 10 (x86/x64). Please note: PCAN-View is a part of our device driver setup.
Easy-to-use tool for updating the firmware of PEAK-System hardware products and CAN and LIN adapters for Windows® 11 (x64/ARM64), 10 (x64).
API for developing applications with CAN CC, CAN FD and CAN XL connections for Windows® 11 (x64/ARM64), 10 (x64).
API for developing applications over CAN connections for Linux.
The PCAN-Basic.NET Assembly is available as a package in the NuGet Gallery. The online documentation is available on our website.
API for developing applications to communicate with ECUs according to the CAN Calibration Protocol (CCP) for Windows® 11 (x64/ARM64), 10 (x86/x64).
API for developing applications to communicate with ECUs according to the Universal Measurement and Calibration Protocol (XCP) for Windows® 11 (x64/ARM64), 10 (x86/x64).
API for transmitting data packets according to the ISO-TP standard (ISO 15765-2) for Windows® 11 (x64/ARM64), 10 (x64).
API for communicating with control devices according to UDS (ISO 14229-1) for Windows® 11 (x64/ARM64), 10 (x64).
API for vehicle diagnostics according to OBD-2 (ISO 15765-4) for Windows® 11 (x64/ARM64), 10 (x64).
The Pass-Thru API and connection to PEAK CAN interfaces via Pass-Thru software. The installation for Windows® 11 (x64/ARM64), 10 (x64) includes: interface DLLs, configuration software and the PCAN-ISO-TP API. Documentation is included in the download.
Compatible software
CAN CC, CAN FD, and CAN XL Interface for High-Speed USB 2.0
The CAN interface PCAN-USB XL ensures an uncomplicated connection to CAN XL, CAN FD, and CAN CC buses via the USB port of a computer. Galvanic isolation of up to 500 Volts decouples the PC from the CAN bus. With its compact plastic casing, it is ideal for mobile applications.
The PCAN-USB XL is delivered ready to use with Windows® and Linux drivers, the PCAN-View monitoring software, and the PCAN-Basic API for developing applications with CAN connection. PCAN-Basic 5 and PCAN-View 6 support the new standard CAN XL.
CAN XL
CAN XL (Extended Data-Field Length) was designed to improve the cooperation of CAN and TCP/IP networks and to enable transmitting larger data streams for use cases such as ECU flashing and software updates. For this, the new standard provides bit rates of up to 20 Mbit/s and data transmission with up to 2048 bytes per message.