Skip to Content
Ixxat

CAN repeaters

Reference Product Price excl. VAT Quantity
1.01.0067.44400 Ixxat CAN-CR220 (2x CAN, 4 kV DC/3.5 kV AC galvanic isolation, termination resistor) 400.00 €
1.01.0067.44400
Ixxat CAN-CR220 (2x CAN, 4 kV DC/3.5 kV AC galvanic isolation, termination resistor)
400.00 €
400.00 € 400.00 €

Terms and Conditions
30-day money-back guarantee
Shipping: 2-3 Business Days

CAN repeater with 4 kV DC/3.5 kV AC galvanic isolation

The Ixxat CAN-CR220 repeater with two CAN interfaces offers galvanic isolation of up to 4 kV DC/3.5 kV AC for 1 second, strengthening the protection of network segments. It improves CAN bus load capacity, establishes a physical coupling of bus systems and offers the flexibility to optimize network structures. The CAN-CR220 complies with DIN/EN 50178 standards.

Ixxat CAN-CR220

Key points

  • Robust industrial use — Designed for industrial environments, meeting high requirements for robustness, temperature ranges and safety.
  • CAN network design flexibility — Helps optimize CAN network structures by enabling extended topologies (stub lines, star and tree topologies).
  • Fast and transparent operation — Minimal impact on real-time behavior, equivalent to a short line length (approx. 40 m/200 ns delay). Transparent transmission, compatible with all higher-layer protocols.
  • Savings through simplified wiring — Optimized topologies allow simplified wiring, reducing the number of cables and installation and maintenance costs.
  • Increased system protection up to 4 kV DC/3.5 kV AC for 1 s — With the CAN-CR220, network components can be galvanically isolated up to 4 kV DC/3.5 kV AC for 1 second (3.2 kV DC/2 kV AC for 1 minute). This reliably strengthens device protection against electronic damage caused by voltage spikes.
  • Network monitoring and fault recovery — In the event of a disturbance, the repeater automatically disconnects the affected segment and reconnects it once the fault has been resolved.
  • Built-in bus termination resistors — The built-in bus termination resistors (120 Ohm, switchable via DIP switch) prevent reflections at line ends and ensure optimal communication.

CAN specifications
CAN modeHigh-speed CAN (ISO 11898-2) with CAN choke
CAN bit rateUp to 1 Mbit/s
CAN transceiverTI SN65HVD251
General
Net width (mm)100 mm
Net height (mm)118 mm
Net depth (mm)22.5 mm
Net weight (g)137 g
Packed width (mm)14 mm
Packed height (mm)4 mm
Packed depth (mm)18 mm
Packed weight (g)219 g
MountingDIN rail mounting (bracket included)
Typical consumption at nominal Vcc (mA)41
Max. consumption at nominal Vcc (mA)100
Supply voltage (V)+9 V to +32 V DC
Isolation4 kV DC/3.5 kV AC for 1 sec., 3.2 kV DC/2 kV AC for 1 min.
Operating temperature °C min.-20 °C
Operating temperature °C max.70 °C
Storage temperature °C min.-40 °C
Storage temperature °C max.85 °C
Relative humidity10 to 95 %, no condensation
Housing materialPolyamide housing for DIN rail mounting
Packaging materialCardboard
Warranty (years)1
Physical characteristics
Contains a batteryNo
Connectors / input / output2 x D-Sub 9 connectors, 1 x power connector
Certifications and standards
CEYes
FCCYes
WEEE categoryIT and telecommunications equipment
IP ratingIP30

  • CAN repeater
  • user manual

Datasheet

CAN repeater with 4 kV DC/3.5 kV AC galvanic isolation

The Ixxat CAN-CR220 repeater with two CAN interfaces offers galvanic isolation of up to 4 kV DC/3.5 kV AC for 1 second, strengthening the protection of network segments. It improves CAN bus load capacity, establishes a physical coupling of bus systems and offers the flexibility to optimize network structures. The CAN-CR220 complies with DIN/EN 50178 standards.

Ixxat CAN-CR220

Key points

  • Robust industrial use — Designed for industrial environments, meeting high requirements for robustness, temperature ranges and safety.
  • CAN network design flexibility — Helps optimize CAN network structures by enabling extended topologies (stub lines, star and tree topologies).
  • Fast and transparent operation — Minimal impact on real-time behavior, equivalent to a short line length (approx. 40 m/200 ns delay). Transparent transmission, compatible with all higher-layer protocols.
  • Savings through simplified wiring — Optimized topologies allow simplified wiring, reducing the number of cables and installation and maintenance costs.
  • Increased system protection up to 4 kV DC/3.5 kV AC for 1 s — With the CAN-CR220, network components can be galvanically isolated up to 4 kV DC/3.5 kV AC for 1 second (3.2 kV DC/2 kV AC for 1 minute). This reliably strengthens device protection against electronic damage caused by voltage spikes.
  • Network monitoring and fault recovery — In the event of a disturbance, the repeater automatically disconnects the affected segment and reconnects it once the fault has been resolved.
  • Built-in bus termination resistors — The built-in bus termination resistors (120 Ohm, switchable via DIP switch) prevent reflections at line ends and ensure optimal communication.