PCAN-MicroMod base boards for dedicated applications
PCAN-MicroMod base boards provide a framework suited to concrete application needs. They are characterized by a wide power supply voltage range as well as protective coupling on the inputs and outputs. CANopen® firmware is available for all PCAN-MicroMod base boards.
The Mix base board combines the common analog and digital functions, complemented by temperature measurement.
Requirements
A PEAK-CAN interface is required for configuration.
Specifications Mix 1
- High-speed CAN connection (ISO 11898-2)
- Bit rates from 10 kbit/s up to 1 Mbit/s
- Compliant with CAN specifications 2.0A (11-bit ID) and 2.0B (29-bit ID)
- Completely configurable using the Windows® software PCAN-MicroMod Configuration
- Operating voltage 8 to 26 V
- Status LEDs for power supply and digital output
- Aluminum casing with spring terminal connectors. Optional DIN rail fixing available
- Extended operating temperature range from -40 to +85 °C (-40 to +185 °F)
- 2 analog inputs:
- Measuring range unipolar 0 to 5 V
- Resolution 10 bit, sample rate 1 kHz
- Measuring range extension optional
- Pull-down circuit
- Protection against under- and overvoltages
- 2 temperature inputs:
- 2 connections for NTC resistors (type EC95F103W)
- Measuring range 0 to 70 °C (32 to 158 °F)
- 6 digital inputs:
- Pull-up or pull-down circuit selectable in groups (3 groups)
- Schmitt trigger behavior, inverting
- Threshold High = 4.8 V, Low = 1.2 V
- Low-pass behavior
- Parallel connection of frequency inputs at 4 digital inputs for alternative use (e.g. on rapid state changes, counting)
- 2 digital outputs/frequency outputs:
- Fast Low-side switch, max. 55 V, 0.75 A
- Short-circuit protection
Specifications Mix 2
- High-speed CAN connection (ISO 11898-2)
- Bit rates from 10 kbit/s up to 1 Mbit/s
- Compliant with CAN specifications 2.0A (11-bit ID) and 2.0B (29-bit ID)
- Completely configurable using the Windows® software PCAN-MicroMod Configuration
- Operating voltage 11 to 26 V
- Status LEDs for power supply and digital output
- Aluminum casing with spring terminal connectors. Optional DIN rail fixing available
- Extended operating temperature range from -40 to +85 °C (-40 to +185 °F)
- 3 analog inputs:
- Measuring range unipolar 0 to 4.1 V
- Resolution 10 bit, sample rate 1 kHz
- Measuring range extension optional
- Pull-down circuit
- Low-pass behavior
- Protection against under- and overvoltages
- 1 analog voltage output:
- Voltage 0 to 10 V (based on 16-bit PWM)
- Load ability 15 mA, short-circuit proof
- 1 analog current output:
- Current intensity 0 to 20 mA (based on 16-bit PWM)
- Current intensity 0 to 20 mA (based on 16-bit PWM)
- 2 digital inputs:
- Pull-up or pull-down circuit selectable for both together (1 group)
- Schmitt trigger behavior, inverting
- Threshold High = 4.8 V, Low = 1.2 V
- Low-pass behavior
- Parallel connection of a frequency input each for alternative use (e.g. on rapid state changes, counting)
- 1 digital output:
- Fast Low-side switch, max. 55 V, 0.75 A
- Short-circuit protection
- 2 temperature inputs:
- 1 connection for a NTC resistor (type EC95F103W)
- 1 connection for a platinum sensor PT1000
- Measuring range 0 to 70 °C (32 to 158 °F)
- PCAN-MicroMod
- PCAN-MicroMod base board in its housing with connectors (Phoenix Contact FK-MCP 1.5/10-ST-3.81 - 1851122)
- PCAN-MicroMod Configuration software for Windows®
- Manual in PDF format
- A PEAK-CAN interface is required for configuration
Package for PCAN-MicroMod, the PCAN-MicroMod Evaluation Kit, and the PCAN-MicroMod base boards. Package including the PCAN-MicroMod Configuration software, the PCAN-MicroMod firmware, the CANopen® firmware, all development files, and documentation (in German and English).
Configuration software for PCAN-MicroMod products for Windows® 11 (x64/ARM64), 10 (x64).
Easy-to-use tool for updating the firmware of PEAK-System hardware products and CAN and LIN adapters, for Windows® 11 (x64/ARM64), 10 (x64).
Compatible hardware
PCAN-MicroMod base boards for dedicated applications
PCAN-MicroMod base boards provide a framework suited to concrete application needs. They are characterized by a wide power supply voltage range as well as protective coupling on the inputs and outputs. CANopen® firmware is available for all PCAN-MicroMod base boards.
The Mix base board combines the common analog and digital functions, complemented by temperature measurement.
Requirements
A PEAK-CAN interface is required for configuration.